Video presentations
V2 – fibreglass ladder · YouTube
maximum height 8.00 m
For professional use
European standard EN 131
European standard EN 131. Indicates compliance with the European technical standard requiring high quality in dimensions and strength.
EN50528:2024
EN50528:2024. Technical standard for insulating ladders used on or near low-voltage installations. “Rated voltage between 50 and 1,000 volts alternating current or between 120 V and 1,500 V direct current” (models certified to this standard: V1, V2, V3, V2F, V3F, Smart1, V6, Moby Fibra, Fly Fibra, Punto Large Plus Fibra).
5-year warranty
The manufacturer specifies a 5-year warranty against manufacturing defects for this product.
Capacity 150kg
The product's maximum total load capacity is 150 kg.
Professional fiberglass ladders suitable for those operators who work next to cables, outlets or other electric energy sources.
The fiberglass frames assure electric insulation but our ladders are also light and easy to manage thanks to the non-skid knurled aluminium rungs.
ECHNICAL FEATURES
• Rung distance 28 cm
• Rung cross-section 27x27 mm
• Capacity 150 Kg
• Number of rungs: from 8 to 16
• Stepladder height: 2.30 to 4.50 m
• Height leant to a wall: 4.05 to 8.00 m
• Base section width 49 cm
• Final section width cm 42
STANDARD PARTS
• Base stabiliser
• Adjustable wrench for stabiliser fastening
• Nylon reinforcement inside stabiliser seat
• Strap preventing uncontrolled ladder opening
• Sliding wheels
• Aluminium opening system
• Non-skid rubber feet
• Device to stop upward movement
• Extension blocking device
• Label and instructions for assembly and use
Available also with rope to be used only leant to wall.
Very important: this model can¬not be used as a stepladder
These ladders are also used for preliminary operations for live work such as checking the voltage, earthing and short-circuiting, etc.
The purpose of this Standard is to provide ladders that have two main functions: access to the parts of the system on which work must be done and protect the worker from electrical risks by providing the level of insulation and maintaining a safety distance between the operator and the potentially live parts of the system.
It concerns insulating ladders for use on low voltage systems or in their proximity.
This Standard, which complies with EN 61477, must be used in accordance with Standards EN 50110-1 and EN 50110-2.
This Standard is published by CEI in English only as it is particularly aimed at specialized sectors.
The source states that this standard applies until 29-04-2027.
The tests are carried out with an electric charge of 36,000 Volts for one minute.
Variants and technical data
| COD. | Description |
|---|---|
| SVETVRUOTE | Transport wheels for the V2 and V3 fibreglass series |
Variants and technical data
| COD. | Sections x rungs | Closed height m | Stepladder height m | Extended length m | Stile profile mm | Weight kg | Inquiry |
|---|---|---|---|---|---|---|---|
| SVETS210 | 2x08 | 2.40 | 2.30 | 4.05 | 70x30 | 14.8 | SVETS210 |
| SVETS220 | 2x10 | 3.00 | 2.90 | 5.20 | 70x30 | 17.7 | SVETS220 |
| SVETV230 | 2x12 | 3.50 | 3.40 | 6.30 | 90x32 | 27.0 | SVETV230 |
| SVETV240 | 2x14 | 4.10 | 4.00 | 7.15 | 90x32 | 30.0 | SVETV240 |
| SVETV250 | 2x16 | 4.60 | 4.50 | 8.28 | 90x32 | 34.0 | SVETV250 |
Interested in this product? Send an inquiry for a quotation, availability or help choosing.